Comparative Study Between the Field Oriented Control and Backstepping Control of Open-End Winding Five-Phase Induction Motor under Open Phase Fault Conditions

dc.contributor.authorSaad khadar
dc.contributor.authorAbdellah Kouzou
dc.contributor.authorMohamed Monir Rezaoui
dc.date.accessioned2024-05-30T13:07:02Z
dc.date.available2024-05-30T13:07:02Z
dc.date.issued2019-02-24
dc.descriptionIntervention
dc.description.abstractAbstract—Open-End Winding Five-Phase Induction Motor (OEW-FPIM) are employed in applications where the reduction in the total power per phase and the highest level of overall system reliability is required, where a self-starting and operation under open phase(s) stand as the most salient features. This paper presents a comparative study of the most powerful control strategies for motor: field-oriented control and backstepping control. The awaited goal is to evaluate the proposed approaches which gives the best performance under open phase fault conditions. The performance of the two control approaches verified and compared by simulation. Provided tests analyze steady and transient states, including an open-phase fault condition. Obtained results prove the interest of the proposed approaches, which ensures the open-phase fault-tolerant capability of OEW-FPIM.
dc.identifier.citationSaad khadar.Abdellah Kouzou.Mohamed Monir Rezaoui.Comparative Study Between the Field Oriented Control and Backstepping Control of Open-End Winding Five-Phase Induction Motor under Open Phase Fault Conditions.. International Symposium on Technology & Sustainable Industry Development, ISTSID’2019. Faculty Of Technology. University Of Eloued. [Visited in ../../….]. Available from [copy the link here].
dc.identifier.urihttps://dspace.univ-eloued.dz/handle/123456789/32860
dc.language.isoen
dc.publisherUniversty Of El-oued جامعة الوادي
dc.subjectfive-phase induction motor
dc.subjectfield-oriented control
dc.subjectBackstepping control
dc.subjectopen-phase fault
dc.subjectopen-end winding
dc.titleComparative Study Between the Field Oriented Control and Backstepping Control of Open-End Winding Five-Phase Induction Motor under Open Phase Fault Conditions
dc.typeIntervention

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Comparative Study Between the Field Oriented .pdf
Size:
938.89 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: