Comparative Study Between the Field Oriented Control and Backstepping Control of Open-End Winding Five-Phase Induction Motor under Open Phase Fault Conditions
No Thumbnail Available
Date
2019-02-24
Journal Title
Journal ISSN
Volume Title
Publisher
Universty Of El-oued جامعة الوادي
Abstract
Abstract—Open-End Winding Five-Phase Induction Motor
(OEW-FPIM) are employed in applications where the reduction
in the total power per phase and the highest level of overall
system reliability is required, where a self-starting and operation
under open phase(s) stand as the most salient features. This
paper presents a comparative study of the most powerful control
strategies for motor: field-oriented control and backstepping
control. The awaited goal is to evaluate the proposed approaches
which gives the best performance under open phase fault
conditions. The performance of the two control approaches
verified and compared by simulation. Provided tests analyze
steady and transient states, including an open-phase fault
condition. Obtained results prove the interest of the proposed
approaches, which ensures the open-phase fault-tolerant
capability of OEW-FPIM.
Description
Intervention
Keywords
five-phase induction motor, field-oriented control, Backstepping control, open-phase fault, open-end winding
Citation
Saad khadar.Abdellah Kouzou.Mohamed Monir Rezaoui.Comparative Study Between the Field Oriented Control and Backstepping Control of Open-End Winding Five-Phase Induction Motor under Open Phase Fault Conditions.. International Symposium on Technology & Sustainable Industry Development, ISTSID’2019. Faculty Of Technology. University Of Eloued. [Visited in ../../….]. Available from [copy the link here].