CORROSION BEHAVIOR OF API N80 STEEL MATERIAL IN ALBIEN WATER
No Thumbnail Available
Date
2018-09-01
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
At Hassi-Messaoud, the recuperation of oil is assisted by injection of water extracted from
Albian aquifer. To increase the injection capacity of the water, API N80 concentric has been
installed along production wells, the difference between the temperature of the water wells
and that of the water injected into the concentric generates a temperature gradient ΔT varying
in depth and up to 16°C. The present study endeavors to examine, first the effect of tempering
temperature on the corrosion behavior of API N80 pipe in Albian water at different
temperature gradients and then to determine the nature of corrosion deposit. Polarizations
results for samples tested at different ∆T shows a general decline in corrosion rate values with
increase in tempering temperature. FTIR and XRD analysis revealed that corrosion scale is
heterogeneous; the formation of various compounds depends strongly on temperature.
Description
Article
Keywords
API N80 pipe; temperature gradient; Albian water; FTIR; Corrosion Scale.
Citation
F. Chelgham,, N. Bouzid, M.Saidi, A. Boumaza, A. Taabouche,CORROSION BEHAVIOR OF API N80 STEEL MATERIAL IN ALBIEN WATER .S .Boudjema,.Journal of Fundamental and Applied Sciences.VOL10 N03.01/09/2018.university of el oued [visited in ../../….]. available from [copy the link here]