THE NONCTILINEAR SPILLWAYDUG SYMMETRICALLY ANDTHERECTILINEAR SPILLWAY (EXPERIMENTAL STUDY)
No Thumbnail Available
Date
2018-05-01
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
جامعة الوادي university of eloued
Abstract
It is clear that the role of spillway is ensured the safety of dams. It is characterized by itsdifferent geometric configurations such as rectilinear spillway and non rectilinear spillwayThe present work was interested in the experimental comparison between the non-rectilinearspillways dug symmetrically (by different depths of hollowing of the alveoli) and therectilinear spiin thin wall of the same width, in order to compare the evacuationperformance between them. This study showed that the performance of non-rectilineaspillways symmetrically excavated, is greater than the discharge capacity of rectilinearin wall in all phases of hydraulic loads
Description
articale
Keywords
rectilinear spillway, nrectilinear spillway, symmetrical digging, evacuationperformance.
Citation
A. Noui 1 , B. Sakaa.THE NONCTILINEAR SPILLWAYDUG SYMMETRICALLY ANDTHERECTILINEAR SPILLWAY (EXPERIMENTAL STUDY).Journal of Fundamental and Applied Sciences.VOL.10 NO.201 May 2018university of eloued23 July 2017http://www.jfas.info