Performance of Grid-Connected Photovoltaic System in south Algeria Adrar city
No Thumbnail Available
Date
2018-12-10
Journal Title
Journal ISSN
Volume Title
Publisher
University of Eloued جامعة الوادي
Abstract
This paper presents results obtained from monitoring a 28 kWp photovoltaic system installed on the rooftop of a Research Unit in Renewable Energies in the Saharan Medium (URER-MS), Adrar, Algeria. The system was monitored in month June 2017. The analysis shows that the value was in the performance ratio and the efficiency of the PV module, system, and the inverter, were 82.4 %, 13%, 12.6 %and 93.8 % in June 2017 respectively. The average DC/ AC power of the PV array was 147.5 kWh/month and 43kWh/month respectively. The observation and analyses exploitation of the collected data can help to evaluate the performance of the PV system connected to the network in the Saharan area of south Algeria (Adrar).
Description
International Symposium on Mechatronics and Renewable Energies El-Oued 10- 11 December 2018
Keywords
Grid-connected PV, performance analysis, Saharan region