VOLTAGE SENSORLESS BASED VIRTUAL FLUX CONTROL OF THREE LEVEL NPC BACK-TO-BACK CONVERTER DFIGUNDER GRID FAULT
dc.contributor.author | Merzou, Imad | |
dc.contributor.author | Mohamed, k | |
dc.contributor.author | Rezaoui, Mounir | |
dc.contributor.author | Bessous, Noureddine | |
dc.contributor.author | Gafazi, Abdsalem | |
dc.date.accessioned | 2023-05-14T09:36:53Z | |
dc.date.available | 2023-05-14T09:36:53Z | |
dc.date.issued | 2019-11-25 | |
dc.description | Article | en_US |
dc.description.abstract | In this paper, a harmonic elimination of grid and stator currents of doubly fed induction generator (DFIG) in case of grid fault without line voltage sensors is proposed . This can be achieved by compensating power based on virtual flux voltage sensorless technique. Direct power control with space vector modulation (DPC-SVM) is used to control both grid-side (GSC)and rotor-side converters (RSC). To achieve the control objective, compensated active and reactive powers are calculated based on virtual flux technique with balanced and harmonic free current as a control target. A theoretical analysis of active and reactive powers under unbalanced voltage source is clearly demonstrated and the effect of grid fault on the performance of DFIG is profoundly discussed. Simulation results verified the effectiveness of the modified control strategy | en_US |
dc.identifier.citation | Merzou, Imad . Mohamed, k. Rezaoui, Mounir. Bessous ,Noureddine. Gafazi ,Abdsalem.VOLTAGE SENSORLESS BASED VIRTUAL FLUX CONTROL OFTHREE LEVEL NPC BACK-TO-BACK CONVERTER DFIGUNDER GRID FAULT. International Journal of Energetica. Vo4. No 02.25/11/2019.faculty of technology. university of el oued. [visited in ../../….]. available from [copy the link here] | en_US |
dc.identifier.issn | 2543-3717 | |
dc.identifier.uri | http://dspace.univ-eloued.dz/handle/123456789/22765 | |
dc.language.iso | en | en_US |
dc.publisher | جامعة الوادي - university of el oued | en_US |
dc.subject | DFIG,DPC-SVM, virtual flux, compensating power, grid fault | en_US |
dc.title | VOLTAGE SENSORLESS BASED VIRTUAL FLUX CONTROL OF THREE LEVEL NPC BACK-TO-BACK CONVERTER DFIGUNDER GRID FAULT | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- VOLTAGE SENSORLESS BASED VIRTUAL FLUX CONTROL OF.pdf
- Size:
- 1.08 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: