Study on the effect of Cetyltrimethylammonium bromide surfactant on static holdup and mother drops’ size in rotating disc columns

dc.contributor.authorNajafabadi, Mehdi Sattari
dc.date.accessioned2023-05-21T09:23:48Z
dc.date.available2023-05-21T09:23:48Z
dc.date.issued2014
dc.descriptionArticleen_US
dc.description.abstractLocal and average static holdup and also mother drops’ size of dispersed phase in rotating disc column (RDC) and rotating sieved disc column (RSDC) have been investigated experimentally for water-kerosene chemical system. Experiments consist of five different CTAB concentrations in continuous phase and for each concentration five different rotor speeds. The presence of used surfactant in continuous phase not only reduced amounts of local and average static holdup in both columns, but it also greatly affected the variation process of local static holdup in the columns. Besides, CTAB reduced mother drops’ size in both columns. As rotor speed went up in RDC, local and average static holdup decreased. In RSDC column, enhancement of rotor speed from zero to 150 rpm caused increase of static holdup but when the speed of rotors went up more, this hydrodynamic parameter decreaseden_US
dc.identifier.citationNajafabadi ,Mehdi Sattari. Rezamohammadi, Ali. Bahmanyar,Hossein. Mohammad Ali Moosaviana. Study on the effect of Cetyltrimethylammonium bromide surfactant on static holdup and mother drops’ size in rotating disc columns.International Journal of Chemical and Petroleum Sciences. Vol 03. No 02.00/00/2014.faculty of technology. university of el oued. [visited in ../../….]. available from [copy the link here]en_US
dc.identifier.issn2253-0932
dc.identifier.urihttp://dspace.univ-eloued.dz/handle/123456789/23589
dc.language.isoenen_US
dc.publisherجامعة الوادي - university of el oueden_US
dc.subjectLiquid-liquid extraction, Rotary disc contactor, Static holdup, Mother drops’ size, Surfactant, Cetyltrimethylammonium bromide (CTAB)en_US
dc.titleStudy on the effect of Cetyltrimethylammonium bromide surfactant on static holdup and mother drops’ size in rotating disc columnsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
STUDY ON THE EFFECT OF CETYLTRIMETHYLAMMONIUM BROMIDE SURFACTANT ON STATIC HOLDUP AND MOTHER DROPS’ SIZE IN ROTATING DISC COLUMNS.pdf
Size:
904.85 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: