Square Wave Voltammetric Determination Of Lead In Commercial Kohl Using A Glassy Carbon Electrode

dc.contributor.authorSaha, M. A.
dc.contributor.authorAlia, M.
dc.contributor.authorRebiai, A.
dc.contributor.authorLanez, T.
dc.date.accessioned2020-10-18T09:52:46Z
dc.date.available2020-10-18T09:52:46Z
dc.date.issued2011-07-01
dc.descriptionArticale in Journal of fundamental and Applied Sciences Vol. 03 N. 02en_US
dc.description.abstractA simple sensitive square wave voltammetric method for the determination of lead contamination of several kohl samples purchased from Algeria retail stores was developed using glassy carbon electrode. The peak current response of 5 standards aqueous solution of lead in NaNO3 as supporting electrolyte was observed showing a linear calibration curve in the concentration range of 4×10-3 – 2.5×10-4 mol/l of lead. Over this concentration range, the equation obtained from the linear calibration graph for lead is Y = 0.00068 + 0.0093x with a correlation coefficient of r2 = 0.987. Following this step, the potential of an aqueous solution of 12 kohl samples containing 2 M nitric acid solution as supporting electrolyte is then swept in the same range of potential (-400 to -700 mV). The amount of lead is then deduced using the linear calibration graph for lead. The results showed up to 52.14% of lead present in kohl, this concentration was over the safe limits of lead set by the world health organization standards. However; only five commercial samples of koen_US
dc.identifier.citationArticale in Journal of fundamental and Applied Sciences Vol. 03 N. 02en_US
dc.identifier.issn1112-9867
dc.identifier.urihttp://dspace.univ-eloued.dz/handle/123456789/7142
dc.language.isoenen_US
dc.publisherUniversity of Eloued جامعة الواديen_US
dc.subjectSquare wave voltammetry, kohl, lead, surma.en_US
dc.titleSquare Wave Voltammetric Determination Of Lead In Commercial Kohl Using A Glassy Carbon Electrodeen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
SQUARE WAVE VOLTAMMETRIC DETERMINATION OF LEAD IN COMMERCIAL KOHL USING A GLASSY CARBON ELECTRODE.pdf
Size:
117.49 KB
Format:
Adobe Portable Document Format
Description:
Articale in Journal of fundamental and Applied Sciences Vol. 03 N. 02

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections