NUMERICAL STUDY AND PERFORMANCE OF A DEW POINT EVAPORATIVE COOLER FOR BUILDINGS IN CONSTANTINE, ALGERIA
dc.contributor.author | Abada, D | |
dc.contributor.author | Rouag-Saffidine, D | |
dc.contributor.author | Maalouf, C | |
dc.contributor.author | Polidori, G | |
dc.contributor.author | Sotehi, O | |
dc.date.accessioned | 2023-05-31T14:58:05Z | |
dc.date.available | 2023-05-31T14:58:05Z | |
dc.date.issued | 2021-01-01 | |
dc.description | Article | en_US |
dc.description.abstract | Due to the ever-growing demand for air-conditioning to bring the indoor air temperature to a comfortable level regardless of the excessive electricity consumption, research is more oriented towards new techniques enabling more energy savings and less adverse environmental impacts. Dew point evaporative cooling systems hold among the most promising because of their ability to reduce the outside air temperature below its wet bulb level while keeping the absolute humidity constant. The current paper aims to report an investigation, which tackles the cool ing cap acity of the system under the Algerian Climate . Constantine city (Algeria) climatic data are retained for the modelling and designing of the system in question. The study involves a variation of its length and air return rate interaction with its ef ficienc y and air temperature supply. | en_US |
dc.identifier.citation | D. Abada, D. Rouag-Saffidine, C. Maalouf, G. Polidori, O. Sotehi2,NUMERICAL STUDY AND PERFORMANCE OF A DEW POINT EVAPORATIVE COOLER FOR BUILDINGS IN CONSTANTINE, ALGERIA .Journal of Fundamental and Applied Sciences.VOL12 N02.01/01/2021.university of el oued [visited in ../../….]. available from [copy the link here] | en_US |
dc.identifier.issn | 1112-9867 | |
dc.identifier.uri | http://dspace.univ-eloued.dz/handle/123456789/25311 | |
dc.language.iso | en | en_US |
dc.publisher | university of el oued/جامعة الوادي | en_US |
dc.subject | Evaporative Cooling, Dew Point Temperature, Numerical Modeling | en_US |
dc.title | NUMERICAL STUDY AND PERFORMANCE OF A DEW POINT EVAPORATIVE COOLER FOR BUILDINGS IN CONSTANTINE, ALGERIA | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- 1316-Corrected Galley Proof-3805-2-10-20230328.pdf
- Size:
- 454.01 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: