SIMULATION OF PHOTON ATTENUATION THROUGH ALUMINIUM USING E-RADIATION SIMULATOR (EGS5 CODE)

Loading...
Thumbnail Image

Date

2019-01-01

Journal Title

Journal ISSN

Volume Title

Publisher

university of el oued/جامعة الوادي

Abstract

Radiation education is necessary for a wide variety of people, such as radiation workers and students of medical imaging. In order to understand radiation behaviour inside the material, we have developed an e-radiation simulator by using Monte Carlo simulation programme (EGS5 code). Anyone who has no programming knowledge will able to simulate photons in a material through this easy to use web-based environment radiation simulator. To validate our simulator, we calculate photon linear attenuation coefficient (µ) of an aluminium material which commonly used as a filter in diagnostic radiology. For the sake of comparison, we calculate at high energy photon of 662 keV to compare our results of µ with the XCOM database and literature. Consequently, the results from the developed simulator comparable with the database and literature for the case of photon attenuation study.

Description

Article

Keywords

Monte Carlo, EGS5, e-radiation simulator, XCOM database, linear attenuation coefficient

Citation

A.H.A.Sabri ,S.M.Tajudin,SIMULATION OF PHOTON ATTENUATION THROUGH ALUMINIUM USING E-RADIATION SIMULATOR (EGS5 CODE) .Journal of Fundamental and Applied Sciences.VOL11 N01.01/01/2019.university of el oued [visited in ../../….]. available from [copy the link here]