Technical Performance of Grid-Connected Rooftop Solar PVs

dc.contributor.authorAsigri, P.Boafo Effah ,F. Opoku , D. Kwegyir , D. Kweku Eshun,A. Owiredu , Asantewaa.. Bin , B. Shafiyu M. -Roy Ekow , S. De
dc.date.accessioned2024-10-20T13:50:39Z
dc.date.available2024-10-20T13:50:39Z
dc.date.issued2023-11-28
dc.descriptionArticle
dc.description.abstractThis paper presents a comprehensive analysis of the technical performance of gridconnected rooftop solar photovoltaic (PV) systems deployed in five locations along the solar belt of Ghana, namely Sakumono, Wa, Bolgatanga, Kumasi, and Kintampo. These locations were selected based on their diverse environmental conditions, offering a representative sample for the study. The study utilized PVSyst software version 7.3 to simulate the performance of the PV systems for each location, using south orientation, which gives the best results in the tilted global irradiation across all locations. According to the simulation results, the average performance ratio for the five locations was 79.7%, indicating the PV systems' highly efficient utilization of the available solar energy. The average final yield, representing the actual energy output, was also measured to be 4.38 kWh/kWp/day for the studied locations. This study demonstrates the technical feasibility of Ghana's grid-connected rooftop solar PV installations. The results underscore the significance of optimal system design and orientation, emphasizing the potential for substantial renewable energy generation. The insights obtained from this study can aid policymakers, investors, and solar energy stakeholders in making informed decisions to promote the widespread adoption of rooftop solar PV systems in the region
dc.identifier.citationAsigri, P.Boafo Effah ,F. Opoku , D. Kwegyir , D. Kweku Eshun,A. Owiredu , Asantewaa.. Bin , B. Shafiyu M. -Roy Ekow , S. De. Technical Performance of Grid-Connected Rooftop Solar PVs. The International Journal of Energetica. Vo8. No 02.28/11/2023.faculty of technology. university of el oued. [visited in ../../ .]. available from [copy the link here]
dc.identifier.urihttps://dspace.univ-eloued.dz/handle/123456789/35278
dc.language.isoen
dc.publisherUniversity of Eloued جامعة الوادي
dc.subjectTechnical performance
dc.subjectGrid-connected rooftop PVs
dc.subjectPerformance ratio
dc.subjectreference yield.
dc.titleTechnical Performance of Grid-Connected Rooftop Solar PVs
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Technical Performance of Grid-Connected Rooftop Solar PVs.pdf
Size:
522.71 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections