A NEW TECHNIQUE FOR SWEAT CHLORIDE DETERMINATION USING MOHR’S SILVER METHOD: DEVELOPEMENT AND ANALYTICAL VALIDATION

dc.contributor.authorLaoufi, Nardjess Rim
dc.contributor.authorBouchenak, Farida
dc.contributor.authorZouakh, Amina
dc.contributor.authorAbdelaziz, Mouna
dc.contributor.authorZerrouk, Abdelhakim
dc.contributor.authorSaddouki, Djamal
dc.date.accessioned2023-05-30T14:37:44Z
dc.date.available2023-05-30T14:37:44Z
dc.date.issued2023-03-13
dc.descriptionArticleen_US
dc.description.abstractThis study presents a new technique for determining chloride ions in the sweat test for the diagnosis of cystic fibrosis. The technique developed is based on Mohr’s silver titrimetric method. The analytical development was performed on three quality control levels (C1, C2 and C3 at 25, 45 and 65 mmol/L respectively) and validated according to the requirements of ISO15189. Repeatability was estimated by the coefficient of variation (CV) at 2.45%, 3.12% and 2.21% for C1, C2 and C3. The CV estimated the intermediate precision at 4.12%, 4.51% and 2.63% for C1, C2, C3. The bias estimated the accuracy at 0.99% for C1, 2.76% for C2 and 2.55% for C3. The assays were performed following a linear calibration curve (equation: Y=0.0001 X + (3 x 10-5) with R2 =0.9995) between 0 and 150 mmol/L. This new technique is a simple and fast alternative using stable and less toxic reagents than the mercurimetric techniqueen_US
dc.identifier.citationNardjess Rim Laoufi, Farida Bouchenak, Amina Zouakh, Mouna Abdelaziz, Abdelhakim Zerrouk, Djamal SaddoukiKhaled Sobhi, A NEW TECHNIQUE FOR SWEAT CHLORIDE DETERMINATION USING MOHR’S SILVER METHOD: DEVELOPEMENT AND ANALYTICAL VALIDATION.Journal of Fundamental and Applied Sciences.VOL15 N02.23/03/2021.university of el oued [visited in ../../….]. available from [copy the link here]en_US
dc.identifier.issnISSN 1112 9867
dc.identifier.urihttp://dspace.univ-eloued.dz/handle/123456789/25151
dc.language.isoenen_US
dc.publisheruniversity of el oued/جامعة الواديen_US
dc.subjectcystic fibrosis; sweat test; Mohr’s method; analytical validation; sweat chlorides.en_US
dc.titleA NEW TECHNIQUE FOR SWEAT CHLORIDE DETERMINATION USING MOHR’S SILVER METHOD: DEVELOPEMENT AND ANALYTICAL VALIDATIONen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1277-Corrected Galley Proof-3810-2-10-20230329.pdf
Size:
630.19 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections