JFAS_Vol 05 N 01
Permanent URI for this collectionhttps://archives.univ-eloued.dz/handle/123456789/7182
Browse
Browsing JFAS_Vol 05 N 01 by Author "Abood, F. A."
Now showing 1 - 1 of 1
- Results Per Page
- Sort Options
Item Detection Of Static Eccentricity Fault In Saturated Induction Motors By Air-gap Magnetic Flux Signature Analysis Using Finite Element Method(University of Eloued جامعة الوادي, 2013-01-01) Halem, N.; Zouzou, S. E.; Srairi, K.; Guedidi, S.; Abood, F. A.Unfortunately, motor current signature analysis (MCSA) cannot detect the small degrees of the purely static eccentricity (SE) defects, while the air-gap magnetic flux signature analysis (FSA) is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE) method. In order to show the impact of magnetic saturation upon the diagnosis of SE fault, the analysis is carried out for saturated induction motors. The index signatures of static eccentricity fault around fundamental and PSHs are detected successfully for saturated motor.